BlueHydra is a Bluetooth device discovery service built on top of the bluez
library. BlueHydra makes use of ubertooth where available and attempts to track
both classic and low energy (LE) bluetooth devices over time.
Installation
Pwnie Sensor
On a Pwnie Express sensor this will be installed as a system service with the regular updates.
Non Pwnie device
On non Pwnie Express systems the files in this repository can be run directly.
Ensure that the following packages are installed:
bluez
bluez-test-scripts
python-bluez
python-dbus
ubertooth # where applicable
sqlite3
libsqlite3-dev
If your chosen distro is still on bluez 4 please choose a more up to date distro. Bluez 5 was released in 2012 and is required.
On Debian-based systems, these packages can be installed with the following command line:
sudo apt-get install bluez bluez-test-scripts python-bluez python-dbus libsqlite3-dev ubertooth
To install the needed gems it may be helpful (but not required) to use bundler:
sudo apt-get install ruby-dev bundler
(from inside the blue_hydra directory)
bundle install
In addition to the Bluetooth packages listed above you will need to have Ruby
version 2.1 or higher installed, as well as Ruby development headers for gem compilation (on
Debian based systems, this is the ruby-dev
package). With ruby installed add the bundler
gem and
then run bundle install
inside the checkout directory.
Once all dependencies are met simply run ./bin/blue_hydra
to start discovery.
If you experience gem inconsistency try running bundle exec ./bin/blue_hydra
instead.
There are a few flags that can be passed to this script:
-d
or--daemonize
: suppress CLI output and run in background-z
or--demo
: run with CLI output but mask displayed macs for demo purposes-p
or--pulse
: attempt to send data to Pwn Pulse
Recommended Hardware
BlueHydra should function with most internal bluetooth cards but we recommend using the Sena UD100 adapter.
Additionally you can make use of Ubertooth One hardware to detect active devices not in discoverable mode.
Note: using an Ubertooth One is not a replacement for a conventional bluetooth dongle.
Configuring Options
The config file is located in /opt/pwnix/data/blue_hydra/blue_hydra.yml
on
Pwnie devices. On systems which do no have the /opt/pwnix/data
directory the service will default to looking in the root of the services
directory (where this README file is located. It will still be called
blue_hydra.yml
The following options can be set:
log_level
: defaults to info level, can be set to debug for much more verbosity. If set tofalse
no log or rssi log will be created.bt_device
: specify device to use as main bluetooth interface, defaults tohci0
info_scan_rate
: rate at which to run info scan in seconds, defaults to 60status_sync_rate
: rate at which to sync device status to Pulse in secondsbtmon_log
:true|false
, if set to true will log filtered btmon outputbtmon_rawlog
:true|false
, if set to true will log unfiltered btmon outputfile
: if set to a filepath that file will be read in rather than doing live device interactionsrssi_log
:true|false
, if set will log serialized RSSI valuesaggressive_rssi
:true|false
, if set will agressively send RSSIs to Pulseui_filter_mode
::disabled|:hilight|:exclusive
, set ui filtering to this mode by defaultui_inc_filter_mac
:- FF:FF:00:00:59:25
, set inclusive filter on this mac, each goes on a newline proceeded by hiphon and spaceui_inc_filter_prox
:- 669a0c20-0008-9191-e411-1b11d05d7707-9001-3364
, set inclusive filter on this proximity_uuid-major_number-minor_number, each goes on a newline proceeded by hiphon and space
Usage
It may also be useful to check blue_hydra --help for additional command line options. At this time it looks like this:
Usage: BlueHydra [options]
-d, --daemonize Suppress output and run in daemon mode
-z, --demo Hide mac addresses in CLI UI
-p, --pulse Send results to hermes
--pulse-debug Store results in a file for review
--no-db Keep db in ram only
-h, --help Show this message
Logging
All data is logged to an sqlite database (unless --no-db) is passed at the command line. The database is located in the blue_hydra directory, unless /opt/pwnix/data exists (Pwnie Express sensors) and then it is placed in /opt/pwnix/data/blue_hydra.
An example for a script wrapping blue_hydra and creating a csv output after run is available here: https://github.com/pwnieexpress/pwn_pad_sources/blob/develop/scripts/blue_hydra.sh This script will simply take a timestamp before blue_hydra starts, and then again after it exits, then grab a few interesting values from the db and output in csv format.
Helping with Development
PR's should be targeted against the "develop" branch. Develop branch gets merged to master branch and tagged during the release process.
Troubleshooting
Parser thread "\xC3" on US-ASCII
If you encounter an error like Parser Thread "\xC3" on US-ASCII
it may be due
to an encoding misconfiguration on your system.
On Debian like systems, this can be resolved by setting locale encodings as follows:
sudo locale-gen en_US.UTF-8
sudo locale-gen en en_US en_US.UTF-8
sudo dpkg-reconfigure locales
export LC_ALL = "en_US"